Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 90
Filtrar
1.
Cureus ; 16(4): e58169, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38616978

RESUMO

Background Rotational deformities in children are currently treated with an osteotomy, acute de-rotation, and surgical fixation. Meanwhile, guided growth is now the gold standard in pediatric coronal deformity correction. This study aimed to evaluate the feasibility of a novel implant intended for rotational guided growth (RotOs Plate) in a large porcine animal model. Methodology A submuscular plate was inserted on the medial and lateral aspect of the distal femoral physis of the left femur in 6 pigs. Each plate was anchored with a screw in the metaphysis and epiphysis respectively. The plates were expected to rotate the femur externally. The right femur acted as a control in a paired design. The animals were housed for 12 weeks after surgery. MRI scanning of both femora was performed before euthanasia after 12 weeks. Rotation was determined as the difference in the femoral version on MRI between the operated and non-operated femur after 12 weeks. Results External rotation in all operated femurs was observed. The mean difference in the femoral version on MRI between operated and non-operated femurs was 12.5° (range 9°-16°). No significant changes in axial growth were detected. Conclusions This study shows encouraging results regarding rotational guided growth, which may replace current invasive surgical treatment options for malrotation in children. However, further studies addressing potential secondary deformities are paramount and should be carried out.

2.
JMIR Hum Factors ; 11: e49696, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38551641

RESUMO

BACKGROUND: The transition from hospital to home after orthopedic surgery requires smooth communication and coordination between patients and their team of care to avoid fragmented care pathways. Digital communication is increasingly being used to facilitate easy and accessible asynchronous communication between patients and health care professionals across settings. A team-based approach to digital communication may provide optimized quality of care in the postoperative period following orthopedic surgery and hospital discharge. OBJECTIVE: This study was divided into two phases that aimed to (1) explore the perspectives of patients undergoing orthopedic surgery on current communication pathways at a tertiary hospital in Denmark and (2) test and explore patients' experiences and use of team-based digital communication following hospital discharge (eDialogue). METHODS: A triangulation of qualitative data collection techniques was applied: document analysis, participant observations (n=16 hours), semistructured interviews with patients before (n=31) and after (n=24) their access to eDialogue, and exploration of use data. RESULTS: Findings show that patients experience difficult communication pathways after hospital discharge and a lack of information due to inadequate coordination of care. eDialogue was used by 84% (26/31) of the patients, and they suggested that it provided a sense of security, coherence, and proximity in the aftercare rearranging communication pathways for the better. Specific drivers and barriers to use were identified, and these call for further exploration of eDialogue. CONCLUSIONS: In conclusion, patients evaluated eDialogue positively and suggested that it could support them after returning home following orthopedic surgery.


Assuntos
Procedimentos Ortopédicos , Alta do Paciente , Humanos , Pesquisa Qualitativa , Comunicação , Centros de Atenção Terciária
3.
JMIR Hum Factors ; 11: e53391, 2024 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-38457798

RESUMO

BACKGROUND: Orthopedic surgical treatment is a transversal task that requires the active involvement of patients, relatives, and health care professionals (HCPs) across various settings. However, after hospital discharge, communication is challenged and undertaken primarily by phone. New digital communication solutions have the potential to create a space for seamless and patient-centered dialogue across discipline and sector boundaries. When evaluating new communication solutions, knowledge about HCPs' needs and perspectives of use must be explored, as it is they who are responsible for implementing changes in practice. OBJECTIVE: This study aimed to (1) investigate HCPs' perceptions of current communication pathways (phase 1) and (2) explore their experiences of using a simple messenger-like solution (eDialogue) for team-based digital communication across settings (phase 2). METHODS: We used a triangulation of qualitative data collection techniques, including document analysis, observations, focus groups, and individual interviews of HCPs before (n=28) and after (n=12) their use of eDialogue. Data collection and analysis were inspired by the Consolidated Framework for Implementation Research (CFIR) to specifically understand facilitators and barriers to implementation as perceived by HCPs. RESULTS: HCPs perceive current communication pathways as insufficient for both patients and themselves. Phone calls are disruptive, and there is a lack of direct communication modalities when communication crosses sector boundaries. HCPs experienced the use of eDialogue as a quick and easy way for timely interdisciplinary interaction with patients and other HCPs across settings; however, concerns were raised about time consumption. CONCLUSIONS: eDialogue can provide needed support for interdisciplinary and cross-sectoral patient-centered communication. However, future studies of this solution should address its impact and the use of resources.


Assuntos
Comunicação , Pessoal de Saúde , Humanos , Pesquisa Qualitativa , Grupos Focais , Análise Documental
4.
Dan Med J ; 71(3)2024 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-38445315

RESUMO

INTRODUCTION: Continuous peripheral nerve blocks (cPNBs) have shown favourable post-operative pain control results but may be associated with a risk for long-term neurological complications. This study sought to examine factors associated with persistent post-operative pain and potential neuropathy after orthopaedic lower-limb surgery with the use of post-operative cPNB. METHODS: Patients who underwent lower limb orthopaedic procedures with cPNBs between November 2021 to May 2022 were included. Patient demographics and perioperative data were noted. At discharge, patients completed the PainDetect (PD) questionnaire and were followed up six months after discharge. RESULTS: Seventy-seven patients with a total of 171 catheters completed the follow up. The median time to follow-up was 214 days after catheter removal, and 18 patients (23%) had a PD score ≥ 13. Univariate analysis showed that multiple variables were associated with a PD score ≥ 13 at the six-month follow-up. Multiple logistic regression showed that a high PD score at discharge, high BMI and longer duration of cPNBs were associated with higher risk of having a PD score ≥ 13 at the six-month follow-up. CONCLUSION: Several factors were associated with a higher risk of having possible neuropathy after six months. BMI, duration of catheter and PD score at discharge were correlated with risk of possible neuropathic pain. FUNDING: None. TRIAL REGISTRATION: The study was a quality control project and therefore did not require registration under Danish law.


Assuntos
Neuralgia , Procedimentos Ortopédicos , Ortopedia , Humanos , Procedimentos Ortopédicos/efeitos adversos , Neuralgia/etiologia , Dor Pós-Operatória/etiologia , Nervos Periféricos
5.
EFORT Open Rev ; 9(2): 119-128, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38308954

RESUMO

Purpose: The objective of this scoping review was to describe the extent and type of evidence of using guided growth to correct rotational deformities of long bones in children. Methods: This scoping review was conducted in accordance with the JBI methodology for scoping reviews. All published and unpublished studies investigating surgical methods using guided growth to perform gradual rotation of long bones were included. Results: Fourteen studies were included: one review, three clinical studies, and ten preclinical studies. In the three clinical studies, three different surgical methods were used on 21 children. Some degree of rotation was achieved in all but two children. Adverse effects reported included limb length discrepancy (LLD), knee stiffness and rebound of rotation after removal of tethers. Of the ten preclinical studies, two were ex vivo and eight were in vivo. Rotation was achieved in all preclinical studies. Adverse effects reported included implant extrusions, LLD, articular deformities, joint stiffness and rebound of rotation after removal of tethers. Two of the studies reported on histological changes. Conclusions: All studies conclude that guided growth is a potential treatment for rotational deformities of long bones. There is great variation in animal models and surgical methods used and in reported adverse effects. More research is needed to shed light on the best surgical guided growth method, its effectiveness as well as the involved risks and complications. Based on current evidence the procedure is still to be considered experimental. Level of evidence: 4.

6.
J Pediatr Orthop B ; 2024 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-38324644

RESUMO

Epiphysiodesis is considered the preferred treatment for children predicted to have leg length discrepancies (LLDs) 2-5 cm at maturity. The aim of this study was to systematically review the existing literature on the effectiveness of permanent epiphysiodesis for LLD treatment, and secondarily to address the reported complications of permanent epiphysiodesis techniques. This systematic review was performed according to PRISMA guidelines. We searched MEDLINE (PubMed), Embase, Cochrane Library, Web of Science and Scopus for studies on skeletally immature patients with LLD treated with permanent epiphysiodesis. The extracted outcome categories were effectiveness of epiphysiodesis (LLD measurements pre/post-operatively, successful/unsuccessful), physeal fusion/arrest, and complications that were graded on severity. Forty-nine studies (3051 patients) were included, 1550 underwent Phemister/modified Phemister epiphysiodesis and 1501 percutaneous epiphysiodesis (PE). Total successful permanent epiphysiodesis surgeries (16 studies) were 73.7% (516/700). Only 13 out of 23 studies had a mean final LLD of less than 1.5 cm. In total, 17.5% (513/2936) of complications were reported. 57 angular deformities were reported (1.9%). Phemister technique had higher percentage of complications (39%) than PE (19.1%) in total, but when failure to achieve adequate reduction in LLD was not included, complication rates for both were close to 14%. However, severe complications were 10.2% for Phemister group and 5.1% for PE. The high complication rates and the relative low success rate call for optimization of the timing and the applied techniques when treating LLD with permanent epiphysiodesis. Phemister technique was found to have higher percentage of severe complications than PE. Registration: PROSPERO (CRD42023435177).

7.
Bone Jt Open ; 5(1): 3-8, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38164740

RESUMO

Aims: The present study seeks to investigate the correlation of pubofemoral distances (PFD) to α angles, and hip displaceability status, defined as femoral head coverage (FHC) or FHC during manual provocation of the newborn hip < 50%. Methods: We retrospectively included all newborns referred for ultrasound screening at our institution based on primary risk factor, clinical, and PFD screening. α angles, PFD, FHC, and FHC at follow-up ultrasound for referred newborns were measured and compared using scatter plots, linear regression, paired t-test, and box-plots. Results: We included 2,735 newborns, of whom 754 received a follow-up hip ultrasound within six weeks of age. After exclusion, 1,500 hips were included for analysis. Sex distribution was 372 male and 380 female, and the mean age at examination was 36.6 days (4 to 87). We found a negative linear correlation of PFD to α angles (p < 0.001), FHC (p < 0.001), and FHC during provocation (p < 0.001) with a 1 mm increase in PFD corresponding to a -2.1° (95% confidence interval (CI) -2.3 to -1.9) change in α angle and a -3.4% (95% CI -3.7 to -3.0) change in FHC and a -6.0% (-6.6 to -5.5) change in FHC during provocation. The PFD was significantly higher with increasing Graf types and in displaceable hips (p < 0.001). Conclusion: PFD is strongly correlated to both α angles and hip displaceability, as measured by FHC and FHC during provocation, in ultrasound of newborn hips. The PFD increases as the hips become more dysplastic and/or displaceable.

8.
Acta Paediatr ; 113(2): 353-361, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38009533

RESUMO

AIM: We investigated the reliability and validity of the Danish child and parent versions of the Gait Outcomes Assessment List (GOAL) questionnaires for ambulatory children with cerebral palsy (CP). METHODS: Translation and cultural adaptations were performed and content validity evaluated. Participants were enrolled between 2016 and 2018 from Aarhus University Hospital, Denmark. Children and parents completed the GOAL questionnaires twice for test-retest reliability. Discriminative validity was evaluated by comparing the child and parent GOAL scores between children with Gross Motor Function Classification System (GMFCS) levels I and II. The concurrent validity of the GOAL questionnaires were investigated by comparing them with Challenge-20, which assesses motor skills in children with CP. RESULTS: We studied 59 children (57% boys) with CP and GMFCS I-II at a mean age of 10.6 years. Test-retest intra-class correlations were excellent for the children (0.91, 95% confidence interval (CI) 0.83-0.96) and good for the parents (0.83, 95% CI 0.67-0.91). GOAL scores decreased with increasing GMFCS (p < 0.05). Both versions correlated well. The mean children's scores were significantly (6.2/100) higher than the parents' (p < 0.001). The GOAL scores correlated positively with Challenge-20. CONCLUSION: The Danish GOAL child and parent questionnaires demonstrated good reliability and content and discriminative and concurrent validity.


Assuntos
Paralisia Cerebral , Criança , Masculino , Humanos , Feminino , Paralisia Cerebral/diagnóstico , Reprodutibilidade dos Testes , Marcha , Inquéritos e Questionários , Pais , Avaliação de Resultados em Cuidados de Saúde , Dinamarca
9.
J Orthop Res ; 2023 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-38053300

RESUMO

This study aimed to develop a method using computer vision techniques to accurately detect and delineate the proximal femur in radiographs of Legg-Calvé-Perthes disease (LCPD) patients. Currently, evaluating femoral head deformity, a crucial predictor of LCPD outcomes, relies on unreliable categorical and qualitative classifications. To address this limitation, we employed the pretrained object detection model YOLOv5 to detect the proximal femur on over 2000 radiographs, including images of shoulders and chests, to enhance robustness and generalizability. Subsequently, we utilized the U-Net convolutional neural network architecture for image segmentation of the proximal femur in more than 800 manually annotated images of stage IV LCPD. The results demonstrate outstanding performance, with the object detection model achieving high accuracy (mean average precision of 0.99) and the segmentation model attaining an accuracy score of 91%, dice coefficient of 0.75, and binary IoU score of 0.85 on the held-out test set. The proposed fully automatic proximal femur detection and segmentation system offers a promising approach to accurately detect and delineate the proximal femoral bone contour in radiographic images, which is essential for further image analysis in LCPD patients. Clinical significance: This study highlights the potential of computer vision techniques for enhancing the reliability of Legg-Calvé-Perthes disease staging and outcome prediction.

10.
Acta Orthop ; 94: 594-599, 2023 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-38093629

RESUMO

BACKGROUND AND PURPOSE: There is inconsistency in the literature regarding the relationship between increased birthweight and risk of developmental dysplasia of the hip (DDH). We aimed to investigate the correlation between birthweight and pubo-femoral distance (PFD), as well as Graf's α angle in newborns undergoing hip ultrasound examination at 6 weeks of age. PATIENTS AND METHODS: Basic newborn characteristics and ultrasound measurements were retrospectively collected during a 1-year study period. We excluded multiple births, newborns born at less than 37 gestational weeks, and incomplete information. Simple and multiple linear regression analyses were performed to evaluate the correlation of birthweight and PFD, and, second, birthweight and α angles including a stratified regression analysis investigating the potential effect modification of sex. RESULTS: 707 newborns (1,414 hips) were included. Mean birthweight was significantly higher for male newborns (P < 0.001). Increased birthweight was positively correlated to PFD values (crude coefficient 0.21, 95% confidence interval [CI] 0.10-0.32) and the correlation was still present after adjusting for sex, family history, and breech presentation (adjusted coefficient 0.18, CI 0.07-0.29). The stratified α angle model for the males was significant for both the crude coefficient (-0.73, CI -1.28 to -0.19) and the adjusted (-0.59, CI -1.15 to -0.03), and also for the females (crude coefficient -1.14, CI -1.98 to -0.31 and adjusted coefficient -1.15, CI -1.99 to -0.31). CONCLUSION: We found that increased birthweight positively correlated to PFD, and negatively correlated to α angle, but this was not of clinical significance.


Assuntos
Luxação Congênita de Quadril , Gravidez , Feminino , Humanos , Recém-Nascido , Masculino , Estudos Retrospectivos , Luxação Congênita de Quadril/diagnóstico por imagem , Luxação Congênita de Quadril/epidemiologia , Peso ao Nascer , Fêmur/diagnóstico por imagem , Exame Físico , Ultrassonografia
11.
JMIR Mhealth Uhealth ; 11: e44442, 2023 07 04.
Artigo em Inglês | MEDLINE | ID: mdl-37283228

RESUMO

BACKGROUND: Smartphones are often equipped with inertial sensors that measure individuals' physical activity (PA). However, their role in remote monitoring of the patients' PAs in telemedicine needs to be adequately explored. OBJECTIVE: This study aimed to explore the correlation between a participant's actual daily step counts and the daily step counts reported by their smartphone. In addition, we inquired about the usability of smartphones for collecting PA data. METHODS: This prospective observational study was conducted among patients undergoing lower limb orthopedic surgery and a group of nonpatients as control. The data from the patients were collected from 2 weeks before surgery until 4 weeks after the surgery, whereas the data collection period for the nonpatients was 2 weeks. The participant's daily step count was recorded by PA trackers worn 24/7. In addition, a smartphone app collected the number of daily steps registered by the participants' smartphones. We compared the cross-correlation between the daily steps time series obtained from the smartphones and PA trackers in different groups of participants. We also used mixed modeling to estimate the total number of steps, using smartphone step counts and the characteristics of the patients as independent variables. The System Usability Scale was used to evaluate the participants' experience with the smartphone app and the PA tracker. RESULTS: Overall, 1067 days of data were collected from 21 patients (n=11, 52% female patients) and 10 nonpatients (n=6, 60% female patients). The median cross-correlation coefficient on the same day was 0.70 (IQR 0.53-0.83). The correlation in the nonpatient group was slightly higher than that in the patient group (median 0.74, IQR 0.60-0.90 and median 0.69, IQR 0.52-0.81, respectively). The likelihood ratio tests on the models fitted by mixed effects methods demonstrated that the smartphone step count was positively correlated with the PA tracker's total number of steps (χ21=34.7, P<.001). In addition, the median usability score for the smartphone app was 78 (IQR 73-88) compared with median 73 (IQR 68-80) for the PA tracker. CONCLUSIONS: Considering the ubiquity, convenience, and practicality of smartphones, the high correlation between the smartphones and the total daily step count time series highlights the potential usefulness of smartphones in detecting changes in the number of steps in remote monitoring of a patient's PA.


Assuntos
Aplicativos Móveis , Smartphone , Humanos , Feminino , Masculino , Estudos de Viabilidade , Exercício Físico , Coleta de Dados
12.
J Orthop Case Rep ; 13(2): 5-9, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37144065

RESUMO

Introduction: X-linked hypophosphatemic rachitis (XLHR) is the most common cause of hereditary rickets that can lead to long bone deformities requiring multiple surgical correction procedures. In addition, high rates of fractures are reported in adult XLHR patients. This study aimed to report a case of femoral neck stress fracture in XLHR patient treated with mechanical axis correction. No previous studies demonstrating a combined valgus correction and cephalomedullary nail fixation were identified in the literature. Case Report: A 47-year-old male patient with XLHR attended the outpatient clinic with severe left hip pain. X-rays revealed a left proximal femoral varus deformity and a femoral neck stress fracture. After 1 month without improvement of pain, and no radiographic sign of healing, correction of the proximal femoral varus deformity and fixation of the cervical neck fracture was achieved by a cephalomedullary nail. At 8 months follow-up, hip pain relief was achieved with radiographic healing of the femoral neck stress fracture and the proximal femoral osteotomy. Conclusion: A review of the literature was performed to identify any case report of femoral neck fractures fixation due to coxa vara in an adult. Both coxa vara and XLHR can cause femoral neck stress fracture. This study presented the surgical technique for treating a rare case of femoral neck stress fracture in a XLHR patient with coxa vara. Pain relief and bone healing were achieved by combined deformity correction and fracture fixation with a femoral cephalomedullary nail. The technique for deformity correction and cephalomedullary nail insertion in the patient with coxa vara is shown.

13.
Children (Basel) ; 10(4)2023 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-37190007

RESUMO

The osseous acetabular index (OAI) and cartilaginous acetabular index (CAI) is often used in diagnosing acetabular dysplasia (AD) in children. We examined the reliability of OAI and CAI in AD diagnostics and compared OAI measurements obtained from radiographs versus MRI. Four raters performed retrospective repeated measurements of the OAI and CAI on pelvic radiographs and MRI scans of 16 consecutive patients (mean age 5 years (2-8)) examined for borderline AD during a period of 2½ years. In MRI, the image selected for analysis by the raters was also registered. Spearman's correlation, scatter plots, and Bland-Altman (BA) plots were analysed for correlation between OAI on pelvic radiographs (OAIR) and MRI scans (OAIMRI), while intra- and interrater reliability was assessed for OAIR, OAIMRI, CAI, and MRI image selection using intraclass correlation coefficients (ICC). ICC values for inter- and intrarater reliability of OAIR, OAIMRI, and CAI were all above 0.65, with no significant differences observed. ICC values (CI) for individual raters' MRI image selection was 0.99 (0.998-0.999). The mean difference (95% CI) between OAIR and OAIMRI was -0.99 degrees (-1.84; -0.16), while the mean absolute difference (95% CI) between OAIR and OAIMRI was 3.68 degrees (3.17; 4.20). Absolute differences between OAIR and OAIMRI was independent of pelvic positioning or time interval between radiographs and MRI scans. OAI and CAI had high Intrarater reliability but mediocre interrater reliability. There was an absolute difference of 3.7 degrees in OAI between pelvic radiographs and MRI scans.

14.
Sensors (Basel) ; 23(5)2023 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-36904954

RESUMO

Determining the presence and severity of knee osteoarthritis (OA) is a valuable application of inertial measurement units (IMUs) in the remote monitoring of patients. This study aimed to employ the Fourier representation of IMU signals to differentiate between individuals with and without knee OA. We included 27 patients with unilateral knee osteoarthritis (15 females) and 18 healthy controls (11 females). Gait acceleration signals were recorded during overground walking. We obtained the frequency features of the signals using the Fourier transform. The logistic LASSO regression was employed on the frequency domain features as well as the participant's age, sex, and BMI to distinguish between the acceleration data from individuals with and without knee OA. The model's accuracy was estimated by 10-fold cross-validation. The frequency contents of the signals were different between the two groups. The average accuracy of the classification model using the frequency features was 0.91 ± 0.01. The distribution of the selected features in the final model differed between patients with different severity of knee OA. In this study, we demonstrated that using logistic LASSO regression on the Fourier representation of acceleration signals can accurately determine the presence of knee OA.


Assuntos
Osteoartrite do Joelho , Feminino , Humanos , Articulação do Joelho , Marcha , Caminhada , Aceleração , Fenômenos Biomecânicos
15.
Acta Orthop ; 94: 51-59, 2023 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-36807707

RESUMO

BACKGROUND AND PURPOSE: Intramedullary bone-lengthening nails have become increasingly popular. The 2 most used and successful nails are the FITBONE and the PRECICE nails. Uniform reporting is lacking on complications of intramedullary bone-lengthening nails. The purpose was therefore to assess and categorize the complications of lower limb bone-lengthening nails and investigate risk factors. PATIENTS AND METHODS: We performed a retrospective review of patients operated on with intramedullary lengthening nails at 2 hospitals. We included only lower limb lengthening with FITBONE and PRECICE nails. Recorded patient data was patient demographics, nail information, and any complication. Complications were graded according to severity and origin classification. Complication risk factors were assessed with modified Poisson regression. RESULTS: 314 segments in 257 patients were included. The FITBONE nail was predominantly used (75%), and most of the lengthenings were performed in the femur (80%). 53% of the patients had complications. 269 complications were identified in 175 segments (144 patients). Device-related complications were most frequent (0.3 complications/segment), followed by joint complications (0.2 complications/segment). An increased relative risk was found for complications in the tibia compared with the femur and for age groups above 30 years compared with the 10-19 years group. CONCLUSION: Complications with intramedullary bone lengthening nails were more frequent than has previously been reported, with 53% of patients sustaining a complication. Future studies need to document the complications meticulously so that the true risk can be established.


Assuntos
Alongamento Ósseo , Fixação Intramedular de Fraturas , Humanos , Adulto , Fixação Intramedular de Fraturas/efeitos adversos , Desigualdade de Membros Inferiores/cirurgia , Estudos de Coortes , Unhas , Pinos Ortopédicos , Fêmur/cirurgia , Fatores de Risco , Estudos Retrospectivos , Resultado do Tratamento
16.
BMJ Open ; 12(9): e062087, 2022 09 22.
Artigo em Inglês | MEDLINE | ID: mdl-36137634

RESUMO

INTRODUCTION: After discharge, patients face multiple risks where timely communication with healthcare professionals is required. eHealth has proposed new possibilities for asynchronous text-based two-way communication between patients and healthcare professionals during this time, and studies show positive effects on clinical outcomes, care coordination and patient satisfaction. However, there are challenges to the adoption of text-based two-way communication, potentially undermining the positive effects in clinical practice. Knowledge of these factors may inform future research and implementations. No reviews have provided an overview of the use of text-based two-way communication after discharge and the identified facilitators and barriers. Therefore, the objective of this scoping review is to systematically identify and map available research that assess the use of text-based two-way communication between patients and healthcare professionals after hospital discharge, including facilitators and barriers to implementation. METHODS AND ANALYSIS: We will include all studies describing the use of text-based two-way communication between patients and healthcare professionals after discharge from hospital. A preliminary search of PubMed (PubMed.gov), EMBASE (Elsevier), CINAHL (EBSCO), PsycINFO (Ovid), Cochrane Library (Wiley), Web of Science (Clarivate) and Scopus (Elsevier) was undertaken on 9 November 2021. The search will be updated for the full scoping review, and reference lists of relevant papers reviewed. Two reviewers will independently screen the literature for inclusion. Data will be extracted and charted in accordance with a data extraction form developed from the research questions and inspired by Consolidated Framework Implementation Research. Findings will be presented in tabular format and a descriptive summary, and reported in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews checklist. ETHICS AND DISSEMINATION: This scoping review will not require ethics approval. The dissemination strategy involves peer review publication and presentation at conferences.


Assuntos
Pessoal de Saúde , Alta do Paciente , Comunicação , Atenção à Saúde , Hospitais , Humanos , Projetos de Pesquisa , Literatura de Revisão como Assunto , Revisões Sistemáticas como Assunto
17.
Children (Basel) ; 9(9)2022 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-36138654

RESUMO

The pubo-femoral distance (PFD) has been suggested as an ultrasound screening tool for developmental dysplasia of the hip (DDH). The aim of this study was to examine if midwives undergoing minimal training could reliably perform pediatric hip ultrasound and PFD measurements. Eight recruited midwives performed two rounds of independent blinded PFD measurements on 15 static ultrasound images and participated in four supervised live-scanning sessions. The midwives were compared to a group of three experienced musculoskeletal radiologists. Reliability was evaluated using inter-rater correlation coefficients (ICC). Linear regression was used to quantify the learning curve of the midwives as a group. There was near complete intra- and inter-rater agreement (ICC > 0.89) on static ultrasound images across both rounds of rating for midwives and radiologists. The midwives performed a mean of 29 live hip scans (range 24−35). The mean difference between midwives and supervising radiologists was 0.36 mm, 95% CI (0.12−0.61) for the first session, which decreased to 0.20 mm, 95% CI (0.04−0.37) in the fourth session. ICC for PFD measurements increased from 0.59 mm, 95% CI (0.37−0.75) to 0.78 mm, 95% CI (0.66−0.86) with progression in sessions. We conclude that midwives reliably perform PFD measurements of pediatric hips with minimal training.

18.
Sensors (Basel) ; 22(14)2022 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-35890969

RESUMO

Sensors with a higher sampling rate produce higher-quality data. However, for more extended periods of data acquisition, as in the continuous monitoring of patients, the handling of the generated big data becomes increasingly complicated. This study aimed to determine the validity and reliability of low-sampling-frequency accelerometer (SENS) measurements in patients with knee osteoarthritis. Data were collected simultaneously using SENS and a previously validated sensor (Xsens) during two repetitions of overground walking. The processed acceleration signals were compared with respect to different coordinate axes to determine the test-retest reliability and the agreement between the two systems in the time and frequency domains. In total, 44 participants were included. With respect to different axes, the interclass correlation coefficient for the repeatability of SENS measurements was [0.93-0.96]. The concordance correlation coefficients for the two systems' agreement were [0.81-0.91] in the time domain and [0.43-0.99] in the frequency domain. The absolute biases estimated by the Bland-Altman method were [0.0005-0.008] in the time domain and [0-0.008] in the frequency domain. Low-sampling-frequency accelerometers can provide relatively valid data for measuring the gait accelerations in patients with knee osteoarthritis and can be used in the future for remote patient monitoring.


Assuntos
Osteoartrite do Joelho , Aceleração , Acelerometria , Idoso , Fenômenos Biomecânicos , Marcha , Humanos , Reprodutibilidade dos Testes , Caminhada
19.
Cancers (Basel) ; 14(15)2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35892824

RESUMO

Novel therapeutic tools are warranted to improve outcomes for children with acute myeloid leukemia (AML). Differences in the proteome of leukemic blasts and stem cells (AML-SCs) in AML compared with normal hematopoietic stem cells (HSCs) may facilitate the identification of potential targets for future treatment strategies. In this explorative study, we used mass spectrometry to compare the proteome of AML-SCs and CLEC12A+ blasts from five pediatric AML patients with HSCs and hematopoietic progenitor cells from hematologically healthy, age-matched controls. A total of 456 shared proteins were identified in both leukemic and control samples. Varying protein expression profiles were observed in AML-SCs and leukemic blasts, none having any overall resemblance to healthy counterpart cell populations. Thirty-four proteins were differentially expressed between AML-SCs and HSCs, including the upregulation of HSPE1, SRSF1, and NUP210, and the enrichment of proteins suggestive of protein synthesis perturbations through the downregulation of EIF2 signaling was found. Among others, NUP210 and calreticulin were upregulated in CLEC12A+ blasts compared with HSCs. In conclusion, the observed differences in protein expression between pediatric patients with AML and pediatric controls, in particular when comparing stem cell subsets, encourages the extended exploration of leukemia and AML-SC-specific biomarkers of potential relevance in the development of future therapeutic options in pediatric AML.

20.
Digit Health ; 8: 20552076221109502, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35783467

RESUMO

Background: Patients with severe bone fractures and complex bone deformities are treated by orthopedic surgeons with external fixation for several months. During this long treatment period, there is a high risk of inflammation and infection at the superficial skin area (pin site). This can develop into a devastating, sometimes fatal, and always costly condition of deep bone infection. Objective: For pin site infection surveillance, thermography technology could be the solution to build an objective and continuous home-based remote monitoring tool to avoid frequent nursing care and hospital visits. However, future studies of infection monitoring require a preliminary step to automate the process of locating and detecting the pin sites in thermal images reliably for temperature measurement, and this step is the aim of this study. Methods: This study presents an automatic approach for identifying and annotating pin sites on visible images using bounding boxes and transferring them to the corresponding thermal images for temperature measurement. The pin site is detected by applying deep learning-based object detection architecture YOLOv5 with a novel loss evaluation and regression method, control distance intersection over union. Furthermore, we address detecting pin sites in a practical environment (home setting) accurately through transfer learning. Results and conclusion: The proposed model offers the pin site detection in 1.8 ms with a high precision of 0.98 and enables temperature information extraction. Our work for automatic pin site annotation on thermography paves the way for future research on infection assessment on thermography.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...